Select a Bar Code Symbology
You can select one or all types of bar code symbologies to use
Condensed DataWizard for advanced transmission arrangement. If
you scan “00” to select all types, the MBC6890 will arrange all
incoming data to meet your pre-defined format. If you want to select
only one type bar code, please select one of the option code listed
below.
UPC-E : 03 Code 128 : 01 Code 11 : 10
Codabar/NW-7 : 06 Code 39 : 07 UPC-A : 02
EAN/CAN/JAN-8 : 05 Telepen : 13 UK/Plessey : 12
EAN/CAN/JAN-13 : 04 Code 32 : 07 MSI/Plessey : 11
UCC/EAN 128 : 01 Code 93 : 09 Code 25 Family : 08
Position Calculation
Data Formatter
If there is a 5-character input data string, please refer to the following to
calculate the actual position for insertion :
x x x x x
00 01 02 03 04 05
Data Verifier, Data Replacer, Data Organizer
If there is a 11-character data string, please refer to the following to
calculate the actual position for identification :
x x x x x x x x x x x
00 01 02 03 04 05 06 07 08 09 10
Application Example
If your bar code label is a 16-digit interleaved 2 of 5 which includes the
information of 6-digit date code, 6-digit serial number and 4-digit unit
price, you want MBC6890 to do the following for you without software
modification :
Apply only Interleaved 2 of 5 to the condensed DataWizard.
Check bar code is actually with 16-digit length.
Allow bar code output whose date code is leading with “9”.
Three outputs with “TAB” suffix.
The date code output should skip “9” and replaced it by “A”.
The serial number output should be led with “SN”.
The unit price output should be skipped the first 2 digits.
Test Bar Code : 981025 123456 9876
Actual Output : A81025
TA B
SN123456
TAB
76
TAB
Please refer to following “Programming Procedure” for details.