Configure Your FuzzyScan
2-27
Condensed DataWizard
i Data Verifier Setting i
PROGRAM M_DEFAULT
Family Code Selection P.C. Parameter Selection Option Code 2nd Option Code
Verifier Control
SS
MS
MS
Disable
Select one bar code symbology
Select all bar code symbologies
FIN
(2 digits)
00
automatic termination
automatic termination
Identified Data Length
SS
MS
Disable
Enable
Determine the identified data length for verification.
FIN
(2 digits)
1st Identified Character
SS
DS
Disable
Enable
2-digits checking position; 1 identified character
FIN
(2 digits)
position
[00-7F]
2nd Identified Character
SS
DS
Disable
Enable
2-digits checking position; 1 identified character
FIN
(2 digits)
position
[00-7F]
3rd Identified Character
SS
DS
Disable
Enable
2-digits checking position; 1 identified character
FIN
(2 digits)
position
[00-7F]
The
Data Verifier
is used to provide advanced verification for error-free scanning and to work as an
Embedded Data Transmitting Filter
.
All data must conform to the
Identified Bar Code Symbologies
,
Identified Data Length
, and one to three
Identified Characters
in the checking position.
Otherwise, the FuzzyScan will not transmit the data to the host computers or terminals, but will instead issue
3 long beeps
for verification error and
skip
the
scanned data.
The Data Verifier checks only scanned data without
Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID
or
Record Suffix
.
Regarding the “
Bar Code Selection
” and “
Position Calculation
” of Data Verifier, please refer to page page 2-33 for details.
Please note that all “
Character
” input should be referred to the
ASCII/HEX Table
listed in Appendix to find matched HEX value.