Configure Your FuzzyScan
2-20
Operation Control
i Operation Mode, Buzzer Tone, Scanning Tolerance i
PROGRAM M_DEFAULT
Family Code Selection P.C. Parameter Selection Option Code
Operation Mode
SS
SS
SS
SS
SS
SS
SS
SS
Low Power mode (Low Power triggering)
Trigger mode (External triggering)
Level mode (Auto power off)
Alternative mode (Periodic power off)
Flash mode (Pulse driven reading)
Force mode (Continued power on)
Toggle mode (Repeat reading)
Diagnostic mode (Test reading)
0
1
2
3
4
5
6
7
Buzzer Tone Adjust
SS
SS
SS
SS
SS
SS
SS
SS
SS
Buzzer tone - mute
Buzzer tone – low
Buzzer tone - medium
Buzzer tone - high
Buzzer tone – extremely high
Good-read beep before data transmission
Good-read beep after data transmission
Power-on beep
No power-on beep
0
1
2
3
4
5
6
7
8
Scanning Tolerance
(Printing Quality Control)
SS
SS
Regular (standard) printing quality
Poor (critical) printing quality
Please note that if you select “Poor printing quality”, you should limit
“Readable
Bar Code Symbology”
and
“Minimum & Maximum Reading Length”
of
each symbology to avoid error reading.
0
1
The “Scanning Tolerance” provides the user with a helpful tool to use when the printing quality of the bar code is poor. This is a programmable feature with
software revision CXX and older for both FBC-3000 series and FBC-6000 series. Units using later software revisions (DXX) perform this feature automatically
without any extra programming. To reduce the error reading rate further, we also recommend that you limit the number of enabled symbologies to only those that
you need to read. And to limit the minimum and maximum reading of each enabled bar code symbology.